Bookmark and Share Printer-friendly version Email to a Friend

High-performance adder uses instrumentation amplifiers

( 01 Dec 2009 )
By Moshe Gerstenhaber and Michael O'Sullivan, Analog Devices, Wilmington, Massachusetts

As instrumentation amplifiers become less costly, they can provide improved performance in applications that operational amplifiers traditionally served. The op-amp adder in Figure 1 has a few shortcomings. First, the inputs have low to medium input impedance, which the input resistor of each signal determines. This arrangement causes gain errors when the source impedance of the driving signal is large or requires the design of low-impedance driving sources. This circuit also has no common-mode-rejection capability, so inputs must be single-ended. The channel with the largest gain limits the performance of the entire system. Higher gain on one channel results in lower bandwidth, higher distortion, and increased system noise on all channels. To limit these effects, even low-performance adders require high-performance, high-bandwidth op amps.

The noise gain of this op-amp adder is 1+10,000/(10||10,000). The input signal with the highest gain and 10Ω input dominates the noise gain, but all inputs suffer increased offset voltage, gain error, noise, and distortion. You can increase input impedance and improve common-mode rejection by using instrumentation amplifiers. The output voltage of an instrumentation amplifier is proportional to the voltage difference between the positive and the negative inputs. You can amplify this signal by connecting a resistor, RGAIN, to the RG pins (Figure 2). The output voltage is generated between the reference pin and the output pin. This arrangement allows you to use the reference pin to cascade multiple signals together in an adder configuration. You can set each instrumentation amplifier to a different gain.

This system has several advantages over the simple op-amp adder. For example, each input has extremely high input impedance and has independent common-mode rejection, which the instrumentation amp connected to that channel determines. The higher the channel gain, the higher the common-mode rejection, and the smaller the resulting error. You can also easily add or subtract signals by using the inverting or noninverting terminals of the instrumentation amplifier, and the amplifier enables the use of differential input signals if you wish. Further, the distortion, noise gain, and bandwidth of each signal are independent of the other signals, leading to lower offset voltage, gain error, noise, and distortion. Figure 3’s THD+N (total-harmonic-distortion-plus-noise) plot demonstrates five times less distortion for the instrumentation-amplifier adder than that of the op-amp adder, even though the instrumentation amplifier has 1MHz bandwidth and operates at 1mA, whereas the op amp has 8MHz bandwidth and operates at 4.5mA.

Click here for the illustrations:

Figure 1, Figure 2, Figure 3



Captions
Figure 1: A typical adder configuration uses a single op amp.
Figure 2: Two instrumentation amplifiers provide increased input impedance in this adder circuit.
Figure 3: The instrumentation-amplifier configuration shows improved THD1N at frequencies greater than 300Hz.

 
Printer-friendly version Email to a Friend
 
Article Rating 
Average Rate: No rating yet
 
Poor Quite Good Good Very Good Excellent
 
 
ADVERTISEMENT
 
Related Content 
 
 
ON-DEMAND WEBCASTS


 
 
Highest Rated  
Feedback Loop  

ADS BY GOOGLE 
 
 
 
ADVERTISEMENT
Press Release 
 
TECHNOLOGY NEWS
 
 
 
PRODUCT NEWS
 
FEATURED SPONSORS
 
 
 
DESIGN CENTERS
 
ADVERTISEMENT
     
Reference Designs 
   
     
 
 
 
 
 

RSS
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   

POLL
What type of environmental regulation do you think will be most beneficial for the tech industry?
Proper recycling and disposal
Push for power efficiency and energy conservation
Chemical/lead regulation
View results
 
     
 
Power Technology E-newsletter 
Power.org Releases Power Architecture 32-bit Application Binary Interface Supplement
EDNA, May 11
POL Regulators Designed for Energy-efficient Computing
EDNA, March 11
Fairchild Revolutionizes Power Savings
EDNA, January 11
Lattice Transforms Board Power and Digital Management
EDNA, November 10
 
Analog E-newsletter 
12V Dual-channel Synchronous Buck Converter Features Integrated FETs
EDNA, February 10
Power MOSFETs features reduced top-side thermal impedanc
EDNA, January 10
 
     
 
KNOWLEDGE CENTER
 
Texas Instruments: DaVinci™ Technology
 
Texas Instruments: Safe Bet Series
 
 
INDUSTRY LINKS
 
Photonics Association (Singapore)
Singapore Industrial Automation Association (SIAA)
Taiwan Semiconductor Industry Association (TSIA)
 
 
OUR SPONSORS
 






Keithley Instruments
With more than 60 years of measurement expertise, Keithley Instruments has become a world leader in advanced electrical test instruments and systems from DC to RF (radio frequency). Our products solve emerging measurement needs in production testing, process monitoring, product development, and research...
 
 
 
     
 

EDN India | EDN Taiwan | EDN Korea | EDN Japan | EDN China | EDN | EDN Europe

 
ABOUT EDN Asia | CONTACT US
   
© 2012 EDN Asia All rights reserved.